ELECTRICAL ENGINEERING // NFPA 70 (NEC) & IEC 60228
30 Amp Wire Size & Voltage Drop Calculator (240V)
Live NEC Table 310.16 ampacity and Chapter 9 voltage drop calculator pre-loaded for a 30A 240V circuit (electric clothes dryers, 30A RV pedestals (120V/240V), and 4,500W tank water heaters).
ADVERTISEMENT // CLS-LOCKED AD SLOT (BCS-WIRE-TOP-01)
Circuit Specification
NEC CH.9 + 310.16Conductor Cross-Section & Drop Graph (SVG)
AWG + IEC MM2LEFT: SCALED CORE DIAMETER VS 12 AWG REFRIGHT: VOLTAGE DROP SLOPE VS NEC LIMIT
Recommended Size
-
-
Actual Voltage Drop
-
-
Rated Ampacity
-
-
Conductor Heat Loss
-
-
NEC Sizing Notes for 30 Amp (240V) Circuits
Key NEC Rule: NEC 240.4(D) requires minimum 10 AWG copper for 30A circuits; for runs over ~95 ft at 240V, upsize to 8 AWG copper to stay under 3% drop.
Typical applications: electric clothes dryers, 30A RV pedestals (120V/240V), and 4,500W tank water heaters. Overcurrent protection: 30A double-pole breaker. Adjust the one-way distance slider above to verify whether voltage drop (>3%) forces upsizing your conductor one gauge thicker.
Embed This SVG Calculator: Contractors and home-improvement blogs can embed this interactive tool for free with one iframe snippet.